| 1 | Five-Function Hospital-Style Electric Bed | Acute care, rehabilitation centers, and long-term-care facilities | Approximately 900 × 2,000 mm | Approximately 400–800 mm | Backrest: approximately 0–70° Legrest: approximately 0–40° Trendelenburg and reverse Trendelenburg commonly available | Typically 200–250 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz input; confirm plug type, medical-grade power supply, leakage current, and battery backup | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 ISO 14971 | Valid test reports from an accredited laboratory; applicable market conformity documentation; risk-management file summary; electrical-safety and EMC reports | Broad clinical functionality, adjustable height, easier patient transfer, and strong suitability for international hospital projects |
| 2 | Low-Height Electric Nursing Bed | Fall-risk reduction, geriatric care, dementia care, and home nursing | Approximately 900 × 2,000 mm | Approximately 250–650 mm | Backrest: approximately 0–70° Legrest: approximately 0–35° Independent height adjustment | Typically 180–220 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; verify battery operation, charging time, plug configuration, and standby power consumption | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 IEC 62366-1 | Usability-engineering documentation, EMC test report, electrical-safety report, and evidence that the lowest position has been tested for stability | Reduces the distance of a potential fall while preserving powered positioning and caregiver access |
| 3 | Heavy-Duty Bariatric Electric Bed | Bariatric wards, specialist rehabilitation, and high-load home care | Approximately 1,200 × 2,000 mm or wider | Approximately 450–800 mm | Backrest: approximately 0–65° Legrest: approximately 0–35° Reinforced deck and wider side-rail options | Typically 300–450 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; confirm motor capacity, circuit protection, battery rating, and local socket compatibility | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 ISO 14971 | Load and stability test results at the declared safe working load; structural test records; braking test; electrical and EMC reports | Higher load capacity and wider sleeping surface; suitable where standard bed dimensions are insufficient |
| 4 | Three-Function Homecare Electric Bed | Home recovery, chronic-care support, and private nursing facilities | Approximately 900 × 2,000 mm | Approximately 400–700 mm | Backrest: approximately 0–70° Legrest: approximately 0–35° Height adjustment may be limited on entry-level configurations | Typically 160–200 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; confirm detachable handset, battery backup, plug standard, and replacement power-supply availability | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 | Declaration of conformity where applicable, electrical-safety report, EMC report, user manual, and service-parts documentation | Lower cost and simpler maintenance while providing the most frequently used backrest, legrest, and height functions |
| 5 | Electric Bed with Integrated Scale | Hospitals and care facilities requiring regular patient-weight monitoring | Approximately 900 × 2,000 mm | Approximately 400–800 mm | Backrest: approximately 0–70° Legrest: approximately 0–40° Integrated weighing system with display or nurse-call integration | Typically 200–250 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; verify scale calibration procedure, battery backup, data interface, and regional plug type | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 ISO 13485 | Scale accuracy and calibration records; electrical and EMC reports; software documentation if data connectivity is included | Reduces manual transfers to a separate scale and supports medication, nutrition, and fluid-management workflows |
| 6 | Electric Nursing Bed with Cardiac-Chair Position | Respiratory care, cardiac recovery, dialysis support, and extended bedside treatment | Approximately 900 × 2,000 mm | Approximately 400–800 mm | Backrest: approximately 0–70° Legrest: approximately 0–40° Chair-position or synchronized contouring function | Typically 200–250 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; confirm actuator duty cycle, emergency battery function, plug standard, and power-failure return behavior | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 IEC 62366-1 | Functional safety assessment, emergency-operation test, EMC report, usability records, and documentation for all powered positions | Supports upright positioning, patient comfort, respiratory management, and easier bedside procedures |
| 7 | Compact Electric Nursing Bed for Small Rooms | Urban apartments, small clinics, residential care, and limited-access rooms | Approximately 850–900 × 1,900–2,000 mm | Approximately 350–700 mm | Backrest: approximately 0–65° Legrest: approximately 0–35° Compact frame with removable or folding components | Typically 150–200 kg, including mattress and accessories | 100–240 V AC, 50/60 Hz; confirm transport dimensions, cable length, plug adapter requirements, and local replacement parts | IEC 60601-1 IEC 60601-2-52 IEC 60601-1-2 | Dimensional and stability test records, electrical-safety report, EMC report, assembly instructions, and local-language labeling | Smaller footprint and easier delivery through narrow doors, elevators, and residential corridors |